HP HSG Array Controller User Manual

Page 203

Advertising
background image

Telnet Commands B-63

Compaq Confidential – Need to Know Required

Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:

Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM

The command syntax is

crossPortTest <nFrames>, <0 or 1>,

where

<nFrames>

determines the number of frames to run

If you do not include the <nFrames> parameter the test runs until you press
Return.

<0 or 1>

determines if a single port looped back to itself is allowed:

0 – default, not allowed

1 – allowed

NOTE: The single port feature of crossPortTest only supports G_Ports when the Switch is
enabled. In order to test a single FL_Port, the Switch must be disabled. If the Switch is
disabled, the single port feature of crossPortTest runs on all ports that are looped back to
themselves.

If no ports are looped back to themselves or to another port of the same type, the Switch
shows an error condition when entering the command. When running the cross port test,
you must set the operating mode value to 0 or 1. Modes 2 and 3 do not send out the ELP
used to discover Switches. If the ELP is not sent, the Switch does not know the port is
connected to another port on the same Switch and the test fails.