Message classification – HP HSG Array Controller User Manual

Page 75

Advertising
background image

Managing the Switch 3-41

Compaq Confidential – Need to Know Required

Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:

Part Number: AA-RHBYA-TE 135267-001 File Name: d-ch3 Managing the Switch Last Saved On: 4/7/99 11:59 AM

Example:

syslogd running on Switch

sw9

is sending log events to the UNIX machine

called

example

. The following is an example of a

No memory

error

generated by the shell. This is a severity 1 (

LOG_CRITICAL

) error. syslogd is

configured to store the errors in:

/var/adm/silkworm

file.

example% egrep sw9 /var/adm/silkworm
Jul 11 16:48:25 sw9 1 0x103d8620 (tShell): Jul 11 16:48:19

Jul 11 16:48:25 sw9Error SYS-NOMEM, 1, No memory
Jul 11 16:48:25 sw9 Traceback:
Jul 11 16:48:25 sw9 _tl+0x40 (0x103a2030)
Jul 11 16:48:25 sw9 _yystart+0x95c (0x1017128c)
Jul 11 16:48:25 sw9 _yyparse+0x694 (0x10172dc4)
Jul 11 16:48:25 sw9 _execute+0xdc (0x1014c06c)
Jul 11 16:48:25 sw9 _shellTask+0x964 (0x1003aea4)
Jul 11 16:48:25 sw9 _shellTask+0x198 (0x1003a6d8)
Jul 11 16:48:25 sw9 _vxTaskEntry+0x10 (0x10114d14)
Jul 11 16:48:25 sw9

Message Classification

syslogd messages are classified according to facility and priority (severity
code). Thus allowing a system administrator to take different actions
depending on the error. The action taken, based on the message’s facility and
priority, is defined in the syslog configuration file. Example configurations are
provided in a following section.

The Switch uses the facility

local7

for all error messages sent to the

syslogd.

UNIX provides eight priorities, whereas the Switch provides four severity
codes (code

LOG_PANIC (0)

causes a reboot and is not sent to the syslogd).

The mapping between the Switch’s severity codes and UNIX syslogd priorities
is provided in Table 3-9.

Table 3-9

syslog Message Classification

Switch

UNIX

LOG_CRITICAL (1)

alert

LOG_ERROR (2)

err

LOG_WARNING (3)

warning

LOG_DEBUG (4)

debug

Advertising