HP HSG Array Controller User Manual

Page 198

Advertising
background image

B-58 StorageWorks Fibre Channel Storage Switch User's Guide

Compaq Confidential – Need to Know Required

Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:

Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM

Table B-12
switchShow Command Field Descriptions

continued

Field

Description

GBIC type

The GBIC type follows the port number. The four GBIC types
include:

-- no GBIC present

sw shortwave GBIC

lw longwave GBIC

cu copper GBIC

Port state

The port state follows the GBIC type. The possible port states
include:

No_Card no card present in this Switch slot

No_Module no GBIC module in this port

No_Light the module is not receiving light

No_Sync the module is receiving light but is out of sync

In_Sync the module is receiving light and is in sync

Laser_Flt the module is signaling a laser fault (defective GBIC)

Port_Flt the port has been marked faulty (defective GBIC,
cable, or device)

Diag_Flt the port failed diagnostics (defective G_Port or
FL_Port card or motherboard)

Online the port is up and running

Lock_Ref the port locking to the reference signal

Comment field

The comment field follows the port state. The possible
comments include:

Disabled the port is disabled

Loopback the port is in loopback mode

E_Port the WWN and Switch name of the other Switch is
shown, the use of this ISL is shown (see FC_SW)

F_Port the WWN of the N_Port is shown

G_Port the port is online but is not yet an E_Port or F_Port

L_Port the port is connected to an arbitrated loop

Advertising