Table 5-4
Port Detail View Page Fields

continued

Field

Description

Rx_flushed

Number of flushed transmissions.

Tx_unavail

Number of interrupted transmissions.

Free_buffer

Number of buffer interrupts.

Overrun

Number of buffer overruns.

Suspended

Number of suspended interrupts.

Parity_err

Number of parity errors.

Frjt

Number of Frame rejected.

Fbsy

Number of frames busy.

Link_Failure

Number of link failure.

Loss_of_sync

Loss of synchronization.

Protocol_err

Protocol error.

Invalid_word

Invalid word (encoding errors inside of frames).

Invalid_crc

Invalid CRC in a frame.

Delim_err

Delimeter error (order set)

Address_err

Address id error (S_ID D_ID)

Lr_in

Link reset in (primitive sequence). Does not apply to FL_Port.

Lr_out

Link reset out (primitive sequence). Does not apply to FL_Port.

Ols_in

Offline resent in (primitive sequence). Does not apply to FL_Port.

Ols_out

Offline resent in (primitive sequence). Does not apply to FL_Port.