American Fibertek SM8P-SFP User Manual

Page 86

Advertising
background image

Rev.A1
18-May-11

78

Join Time:

Used to declare the Join Time in unit of centisecond. Valid time range:
20 –100 centisecond, Default: 20 centisecond.

Leave Time:

Used to declare the Leave Time in unit of centisecond. Valid time range:
60 –300 centisecond, Default: 60 centisecond.

Leave All Time:

A time period for announcement that all registered device is going to be
de-registered. If someone still issues a new join, then a registration will
be kept in the switch. Valid range: 1000-5000 unit time, Default: 1000 unit
time.

Default Applicant Mode:

The mode here means the type of participant. There are two modes,
normal participant and non-participant, provided for the user’s choice.

Normal:

It is Normal Participant. In this mode, the switch participates
normally in GARP protocol exchanges. The default setting is
Normal.

Non-Participant:

It is Non-Participant. In this mode, the switch does not send or
reply any GARP messages. It just listens messages and
reacts for the received GVRP BPDU.

Default Registrar Mode:

The mode here means the type of Registrar. There are three types of
parameters for registrar administrative control value, normal registrar,
fixed registrar and forbidden registrar, provided for the user’s choice.

Normal:

It is Normal Registration. The Registrar responds normally to
incoming GARP messages. The default setting is Normal.

Fixed:

It is Registration Fixed. The Registrar ignores all GARP
messages, and all members remain in the registered (IN)
state.

Forbidden:

It is Registration Forbidden. The Registrar ignores all GARP
messages, and all members remain in the unregistered
(EMPTY) state.

Restricted Mode:

This function is used to restrict dynamic VLAN be created when this port
received GVRP PDU. There are two modes, disable and enable,
provided for the user’s choice.

Advertising