Displaying show mpls-labels commands

It displays the incoming labels binding received from the neighbors and the out-going label binding distributed by the
system. When no specific FEC is defined, the system shows all FECs.

Usage

Show mpls-labels <standard | vc> <out | in> [<FEC identifier>]

Parameter(s)

<standard | vc>

Standard labels are the first labels on the stack, while vc labels (tunnels) are the second lable on the stack.

<out | in>

Lables that are out-going or incoming.

<FEC identifier>

It is the FEC (Forward Equivalence Class) identifier.

Example(s)

Standard in:

Standard out:

Host> show mpls-labels

Note:

The system default value is 0 (which means all FECs).

Host> show labels standard in

FEC ID

IP destination FEC

Label

Next-Hop

Interface

1

192.168.1.0/24 123876 10.0.1.8 Ethernet 1

2

212.8.1.0/24 1034

10.0.1.3 Ethernet 1

Host> show labels standard out

FEC ID

IP destination FEC

Label

1

192.168.1.0/24 123876

2

212.8.1.0/24 1034

Advertising