ElmoMC Multi-Axis Motion Controller-Maestro User Manual

Page 162

Advertising
background image

10.2.2.3

Features of Profile Position Operating Mode Using for

Group (Vector)

Profile position motion for the DS402 Group (Vector) can be implemented by the
following command sequence:

function run()

int val
sync( 0, 10 )

//work with DS402 motion object required sync mechanism

g1.opm=1

//select operation mode for group g1


g1.gto=10000

//statusword waiting timeout

g1.prv=2000

//set profile velocity

g1.pac=10000000

//define acceleration

g1.pdc=10000000

//define deceleration

g1.qsdc=10000000

//define quick stop deceleration

g1.psw=200

//define position windows

g1.pswt=2

//define position windows time

g1.mo=1

//motor on command

g1.pa=0

//set absolute target position value

g1.bg

//start

motion

val=g1.gwm

//wait for motion completed

if( (val&1024) == 1024)

//bit 10 of SW is ON for target reached


a1.sp=5000

//set profile velocity for axis a1 (member of g1)

a1.ptp=2000

//set target position for axis a1 (member of g1)

a1.snp

//apply new position for axis a1 (member of g1)


a2.prv=5000

//set profile velocity for axis a2 (member of g1)

a2.ptp=2000

//set target position for axis a2 (member of g1)

a2.snp=2000

//apply new position for axis a2 (member of g1)


g1.bg

//synchronically

motion

start for all members of g1

g1.gwm

//wait for motion complete for all members of g1

end if

g1.mo=0

//motor off command

end function

Vector (Group) must be synchronized when working with the following commands: bg
(start motion), st (stop motion), pcwd (controlword) and gv, ip, hm – commands for other
operating modes. Synchronization is achieved via sync messages on a CAN bus.