2 using syntax, 1 command interpreter – ElmoMC Multi-Axis Motion Controller-Maestro User Manual

Page 210

Advertising
background image

Maestro

Software Manual

Ethernet/IP Communication

MAN-MASSW (Ver. Q)

11-8

5. Click on OK to complete the operation. The Workspace window of the EIP View

page will appear as follows:

Figure 11-12: EIP Adapter

6. To create device’s tags, use the context menu Add Tag. The following dialog box

will open:

7. In the Tag Name field, enter the tag

name

used for Read/Write.

8. In the Tag Type field, select the

appropriate type (BOOL, SINT, INT,
DINT, REAL). Use the Tag
Dimension
field to define the tag as
an array.

NOTE: The Tag Name, Type and

Dimensions MUST be the same as

defined on the Rockwell side.

Figure 11-13: Tag Properties

11.5.1.2

Using syntax

11.5.1.2.1

Command interpreter

Get Tag syntax is

[Device Name] . [Tag Name]

[Device Name] . [Tag Name][index]

where index need if tag is array.