Motion Control with PTO and PWM Chapter 7

Sample Motion Wiring Configuration on 2080-LC30-xxQBB/2080-LC50-xxQBB

Motion Control Function
Blocks

Motion control function blocks instruct an axis to a specified position, distance,
velocity, and state.

Function Blocks are categorized as Movement (driving motion) and
Administrative.

2080-L

C30-xxQBB

2080-L

C50-xxQBB

K

inetix3

+DC 24

-DC 24

+CM0

+CM1

O-00

O-03

O-06

O-07

-CM0
-CM1

Pin 1, 2

Pin 12(CLK-)
Pin 49(CLK+)

Pin 14(DIR-)
Pin 25(DIR+)
Pin 3(Enable)

Pin 7(RST)

1

2

24V

Power
Supply

24V

Power
Supply

_

Enc
oder

Mot
or

Encoder signal cable

Motor power cable

+

+

Notes:

(1) Drive Enable (Pin 3) and Reset Drive (Pin 7) will be operating as sinking inputs when (Pin 1,2)

connected to

+

of the Power Supply 2.

46047

To help you configure Kinetix3 drive parameters so the drive can communicate and be controlled
by a Micro830/Micro850 controller, see publication

CC-QS025

.

Administrative Function Blocks

Function Block Name

Function Block Name

MC_Power

MC_ReadAxisError

MC_Reset

MC_ReadParameter

MC_TouchProbe

MC_ReadBoolParameter

MC_AbortTrigger

MC_WriteParameter

MC_ReadStatus

MC_WriteBoolParameter

MC_SetPosition

Advertising