Motion Axis State Diagram

Continuous

Motion

Discrete

Motion

Stopping

ErrorStop

StandStill

Disabled

Homing

MC_MoveAbsolute

MC_MoveRelative

MC_Halt

MC_MoveAbsolute; MC_MoveRelative; MC_Halt

MC_MoveVelocity

MC_MoveVelocity

MC_Stop

MC_Stop

MC_Stop

Done

Error

Error

MC_Stop

MC_Reset and
MC_Power.Status=FALSE

MC_Home

Done

Error

MC_MoveAbsolute

MC_MoveRelative

Error

MC_Reset

MC_MoveVelocity

Note 5

Note 3

Note 2

Note 4

Error

Note 6

Note 1

NOTES:

(1) In the ErrorStop and Stopping states, all function blocks (except MC_Reset), can be called although they will not be executed.

MC_Reset generates a transition to the Standstill state. If an error occurs while the state machine is in the Stopping state, a transition to
the ErrorStop state is generated.

(2) Power.Enable = TRUE and there is an error in the Axis.

(3) Power.Enable = TRUE and there is no error in the Axis.

(4) MC_Stop.Done AND NOT MC_Stop.Execute.

(5) When MC_Power is called with Enable = False, the axis goes to the Disabled state for every state including ErrorStop.

(6) If an error occurs while the state machine is in Stopping state, a transition to the ErrorStop state is generated.