Arc Machines, Inc. Model 307 Orbital Tube Welder Training

Document No. 740096

Chapter 2. Page 2.

Rev. A

S

afe Use of Orbital Welding Equipment

DO’s

1. Do

VERIFY

correct AC Power Source (100 or 240 VAC

single phase) before plugging in the Model 307.

2. Do Autocal weld head (or select Manual Option)

each time the Model 307 is connected to a different

weld head. The weld head must be calibrated to the

power supply it is connected to.

3. Do

CHECK

ALL

CABLE

AND

QUICK

-

DISCONNECT

FITTINGS

to insure proper seating and that protective

boots are in place.

4. Do check for G

AS

LEAKS

on all external Gas fittings.

5. Do

PROTECT

WELD

HEADS

by storing in shipping

container (or otherwise suitably protected) when not in

use.

6. Do

KEEP

PROTECTIVE

COVERS

ON

THE

MOTOR

CABLE

CON

-

NECTORS

when not in use.

7. Do insure that the

PROPER

E

LECTRODE

is installed in

the weld head.

8. Do use a

REGULATOR

AND

FLOWMETER

designed for the

gas that is being used and suitable for the purity

requirements of the application.

Model 307 Do’s and Don’ts