I.d. pressure, Purging techniques – Arc Machines 307 User Manual

Page 159

Advertising
background image

Arc Machines, Inc. Model 307 Orbital Tube Welder Training

Document No. 740096

Chapter 16. Page 6.

Rev. A

is sometimes used to flush out volatilized materials from the weld area be-

fore they can be deposited in order to prevent the "blue halo."

I.D. Pressure
Caution must be exercised to avoid overpressurizing the weld. If a high flow

rate is used, a larger exit orifice for the purge gas is required to prevent I.D.

concavity ("suck-back") or a blow-out. The exit orifice diameter should be

measured and recorded for each different size of tubing. A pressure gauge

(Magnehelic

®

or equivalent) connected to a tee inserted at the weld joint is

used in high purity applications to adjust the flow rate (or orifice size) that

will result in the amount of I.D. pressure necessary to produce a flat, fully

penetrated I.D. weld bead. The tee is then removed from the joint and the

weld head installed on the joint to make the weld using the predetermined

flow rate (orifice diameter). Flow rates, purge times, orifice sizes and inter-

nal pressure should all be documented as part of the Standard Operating

Procedures (SOPs) and, once established, followed routinely by all welding

personnel. See SEMI Standard F79-0703 Table 1. for suggested I.D.purge

settings for high-purity applications.

Purging techniques
Sound purging procedures are an essential component of a successful orbit-

al welding program. Successful purging requires gas of appropriate quality

for the application and maintaining the gas purity up to the point of use, i.e.,

the O.D. and I.D. of the weld puddle and HAZ. This requires air-tight hoses

and connectors. Welded stainless steel tubing with face seal fittings are

used for the highest purity semiconductor applications so that only stainless

steel comes into contact with the weldment. All types of plastic tubing are

permeable to atmosphere to some degree. The Polyflow

®

(polyethylene)

tubing supplied with the Arc Machines equipment is very good. The SEMI

specification recommends PFA plastic tubing, but in either case the plastic

tubing should be restricted to less than 10 feet in length. Specifications for

the various types of plastic tubing listing permeability to oxygen and mois-

ture can be obtained from the plastic tubing manufacturers. The use of rub-

ber or similar type purge hoses is not consistent with high-quality welding.

Some type of diffuser may be used to disperse the argon flow to assure

that the entire weld joint is covered. A diffuser at the connection of the gas

hose to end cap can be used to disperse the argon stream entering the tube

or pipe ID. This can also be accomplished by a filter. Contractors have de-

veloped a variety of devices and techniques to assure that the entire I.D.

weld joint is adequately covered by purge gas.

Analytical equipment such as oxygen and moisture analyzers can be

used to verify that purge gas exiting the I.D. of the tube or pipe being weld-

ed has approximately the same level of purity as the source gas. If it does

not, the location of the leak(s) must be found.