Arc Machines, Inc. Model 307 Orbital Tube Welder Training

Document No. 740096

Chapter 5. Page 5.

Rev. A

Start Position - The Start Position documents the start

location of the electrode (when the tube is in the horizontal

5G position). The default position is 3 O’clock. Selection of

a different start location requires the operator to position

the weld head accordingly. Since most thin-wall tube weld-

ing applications are not significantly affected by the Start

Position, this information is normally used only for heavy-

wall applications.

PROGRAMMABLE VARIABLES:

Level/Segment Parameters -

Level parameters are parameters

that may be changed during the weld

sequence.

Level Position - Level Position is

the location of the electrode at

the end of a particular level. If

Level Time is changed, position

values will be adjusted accord-

ingly.

Primary Amps - Background

Amps. When Pulse Mode is ON,

amperage is pulsed between the

Primary (high) amp setting and

the Background (low) amp set-

ting.

Primary Pulse (Time) - Background Pulse (Time).

The Primary and Background pulse timers indicate the

duration of Primary and Background Amps.