Arc Machines 307 User Manual

Page 22

Advertising
background image

Arc Machines, Inc. Model 307 Orbital Tube Welder Training

Document No. 740096 Chapter 3. Page 6
Rev. A

Table 2. Buttons used on the Model 307 Power Supply

Paste Schedule inserts a copied schedule into another folder of the

same power supply or into a folder in a Library in remote power supply.

Rename Schedule allows the user to change the name of a selected

schedule by typing in the new name from the keyboard.

Level Advance. Touching the Level Advance button on the touch screen

or on the remote pendant during the weld sequence advances the

program to the next level.

Add Level. When the Levels screen of a weld schedule is visible addi-

tional Levels may be added to the schedule by touching this button.

Plus or Minus 1%. Both Primary and Background Amps of a weld

schedule are changed 1% up or down by touching one of these buttons.