Arc Machines, Inc. Model 307 Orbital Tube Welder Training

Document No. 740096 Chapter 10. Page 5.
Rev. A

Weld Schedule Counter and Alert Reset

From the Main Weld Schedule screen touching the Counter Reset button

will bring up the Counter/Alert Indicator screen that allows the user to either

reset the alert counter to a new number, reset the weld counter to zero,

change the alert message and/or disable the alert.

Selecting either option from the above screen brings up the

Weld Counter Reset Setup screen which can be customized to weld sched-

ule that is currently open. For example, an alarm may be set to tell the user

to change the electrode after 15 welds or to make a test coupon. Type in

alarm message from the keyboard.