WELD HEAD INSTALLATION TO ADAPTER CABLE

The weld head cable connects to the adapter cable, except for the

Model 9-500 and Model 9-250 which plug into the power supply or exten-

sion cable using a pigtail. Insert the adapter cable GROUND, ELECTRODE,

and GAS connectors into the mating weld head cable connectors. Pull

back the collar of the female quick-disconnect fitting of the electrode and

ground connectors and twist the male connector into place.

Slide the rubber boots together (male boot should cover connec-

tion first) and secure them in place, being careful not to dislodge

the connectors. The boots protect the connectors and prevent

shorting to ground.

Remove dust covers from CONTROL cables, and insert the

adapter cable connector into the head connector. Tighten by

hand and screw dust caps together.

Pull back on the collar of the
female connector. Make con-
nection with collar pulled back.

WELD HEAD MOTOR

ELECTRODE /
GROUND

WELD HEAD GAS CONNECTION

COOLANT CIRCULATES THROUGH HOSES IN THE ADAPTER CABLE.

Weld Head Motor Connector to 307

307 Adapter Cable to Weld Head

Connector

Adapter cable

electrode and

ground

connectors

to weld head

cable