Arc Machines, Inc. Model 307 Orbital Tube Welder Training

Document No. 740096 Chapter 13. Page 3
Rev. A

Manual Weld Head Calibration

To calibrate a weld head manually, touch the Calibration Icon , select Manual

and then use a program with appropriate RPM and time for the weld head as

shown in Table 1. At a rotational speed of 1 RPM, the rotor should com-

plete one Revolution (360°) in 60 seconds.

The manual calibration program should have no travel start delay (0.0

sec) and no Downslope time (0.0 sec). Calibration programs must be run

in Test Mode Only. If the weld head goes too far or comes up short, adjust

the screw on the calibration pot counter clockwise (CCW) to slow it down or

clockwise (CW) to speed up the rotation. Repeat as necessary.

Schedule for

weld heads

calibrated at 4

RPM for 15 sec.

If the travel

speed is

correct and

degrees set

to 360°, time

will be

entered

automatically