Arc Machines, Inc. Model 307 Orbital Tube Welder Training

Document No. 740096 Chapter 9. Page 15.
Rev. A

Hand Torch Weld Schedule - Weld Levels

The Weld Levels screen has parmeters that may be changed for each level of

a weld sequence. For a manual torch program, one level is usually sufficient.

Pulse Mode is ON for this program but some users may prefer constant

current for tack welds. Primary and Background Amps (current) may be

adjusted to provide more heat for heavier wall thickness. Tack welds should

not penetrate to the I.D. Tack welds must be fully consumed by the orbital

weld on the I.D. and O.D.

On the screen below Primary Amps have arbitrarily been set to 50 and

Background Amps to 20. Adjust penetration using the + Amps button. An I.D.

purge IS STRONGLY RECOMMENDED for manual tack welding to prevent

I.D. oxidation.