Primary Travel (speed) - Background Travel

(speed). If Travel Mode is set to CONT (continuous) the

electrode rotation will remain at the Primary Travel (RPM)

setting. If the Travel Mode is set to STEP the electrode

rotation (RPM) will alternate between the Primary and

Background travel (RPM) settings.

Pulse Mode - Pulse Mode is selectable by a pull-down

menu in each level. Pulse Mode ON pulses the current

between the primary and background amps by enabling the

pulse timers and background amps. Pulse Mode OFF pro-

vides full primary amps. Pulse Mode External allows the

pulse to be triggered by an external source.

Travel Mode - Electrode travel mode can be selected from

the pull-down menu in each level. In Travel Mode CONT

the electrode travels at a constant speed; in Step the elec-

trode may travel at different speeds during the primary and

background pulse times, typically primary travel is set to

zero in step mode; in OFF the electrode does not move; in

External travel may be triggered by an external device.

Travel Mode: Weld bead appearance in CONT Travel mode (Left) and

STEP Travel mode (Right). STEP mode is typically used on wall thick-

nesses greater than 0.083 in.