Arc Machines, Inc. Model 307 Orbital Tube Welder Training

Document No. 740096

Chapter 4. Page 8.

Rev.A

replacement pump if

required). Flow/no flow

indicators are of both visual

and electronic design.

The 307 CW is filled from a

spout on the top of the unit. A

Fill Indicator on the front panel

indicates the fill level, while a

flow indicator rotates to indi-

cate coolant flow.

Note: Pump does not self- prime well. Monitor Fill Level after

cables have filled with coolant.

CAUTION: Remove Coolant before shipping the 307-CW.

The Coolant Fault must be turned on when the

M307-CW is in use.

The Fault Setup Screen is accessed from the System Setup Functions

button on the Opening screen which opens the System Setup Screen; se-

lect Faults which opens the Fault Setup Screen (shown below) and

touch the Coolant button. A Green light is ON when fault is enabled.

Fill spout

Fill Level

Flow Indicator

Model 307-CW (front)

Green light
shows fault
enabled