Installation of Tube Clamp Inserts
Tube clamp inserts (TCIs) are used to hold the tubes or other weld compo-

nents in place for welding. Each tubing diameter welded in a particular head

must have two sets of TCIs or fitting clamp inserts, one set on each side of

the head. The 9-500 and 9-250 type weld heads use clamp assemblies for

this purpose. Adapters are available for TCIs of the large heads so they may

be used in more than one size of weld head.

Two sets of TCIs are installed in the 9-1500 weld head. Here the

operator installs a TCI by securing the single screw with an Allen

wrench. Each set of TCIs has a unique marking and members of a

set should be installed on the same side of the head.

The 9-750 weld head has solid TCIs.

The outside of the TCI is marked OUT

and should be oriented to the outside

of the head.

Top TCI

Bottom TCI