Arc Machines, Inc. Model 307 Orbital Tube Welder Training

Document No. 740096 Chapter 6. Page 7
Rev. A

Security Administration permits the classification of users as Operators,

Supervisors and Programmers with defined access to M 307 functions. Users

may be added, removed, or their classification changed.

Touching the Faults button from the System Setup Functions brings up the

Faults Setup Screen. Fault functions are enabled by selecting the button for

Stubout, Input AC, High Arc, Gas, Coolant or external faults. The green light

indicates that the fault is enabled. Pulldown menus on the External Faults

offer the choice of a Warning Only if a fault is detected, or the 307 will enter

Downslope or Stop the Weld sequence immediately if the selected fault

occurs.