Arc Machines, Inc. Model 307 Orbital Tube Welder Training

Document No. 740096 Chapter 18. Page 7.
Rev. A

Selectable Outputs include:

1) Operator Info: Operator (Logon) Name and security classification if

logged on will appear as text.

2) Project Data: Text will be added to the output for all items entered

on the Weld Identification Information screen.

3) Level Time (if selected)

4) Current (if selected)

5) Voltage (if selected),

6) Travel (Motor Servo 1, if selected)

7) Wire feed (Motor Servo 2, if selected)

8) Head position (if selected)

9) Events: i) Elapsed Time, Event message ii) Events will be printed on

a separate Line

10) The Start and Stop times of the streaming data output can also be

selected. Start of the data stream can be: Start Output At: Start of

Prepurge, at arc start, or at the end of upslope.

Stop of the data stream - Stop Output At: Start of Downslope, end of

Downslope, or at end of Postpurge.

Sampling of the Data
Primary values and background values will both be sampled separately with

sampling delays built-in to prevent sampling the feedback data during the

transition periods. When a deviation occurs during the weld sequence, the

event will be logged with the following information: time the event

occurred, expected value, and the actual value. These events will be

stored as part of the Weld Data Record, and included in the “end of

sequence” report.