Level Amps: Typically, the heat required to achieve penetration

at the beginning of a weld will need to be reduced during the

weld to avoid overpenetration. There are several methods of cal-

culating intermediate level Primary Amps.

1.The first method works for any number of levels. If the

amperage is reduced by 20% from Level 1 to the Last Level,

then the Last Level will be equal to 80% of Level 1. To calcu-

late the amount of primary amp reduction for each level, sub-

tract the Last Level amps from Level 1 amps and divide the

difference by the number of levels you are creating minus 1

level.

“Real World” Level 1 Primary Amperage Calculations

Wall Thickness

(in).

Primary Level 1

Amps based on 1

amp per 0.001”

% Correction

Primary

Amps based

on

correction

0.035

35 Amps

0

35 Amps

0.049

49 Amps

+10

54 Amps

0.065

65 Amps

+15

75 Amps

0.083

83 Amps

+15

96 Amps

0

20

40

60

80

100

120

0.035

0.049

0.065

0.083

0.109

0.12

Wall Thickness - Inches

Am

ps

1 Amp per 0.001”

Correction

Primary Amps/Wall Thickness