Arc Machines, Inc. Model 307 Orbital Tube Welder Training

Document No. 740096

Chapter 4. Page 12.

Rev.A

Model 307 Accessory Connections

The Model 307 Power Supply features several types of connectors for

optional accessories with control or communication functions.

Data. The RS-232 Communications Port outputs streaming digital

data to an external device during the weld sequence. The output

is in ASCII format and a standard RS-232 cable is required.

The Auxiliary Plug may be used to connect an external device such as an

oxygen analyzer to give a fault condition unless certain conditions are met.

Connect device to the Auxiliary pin connector, enable External Fault on the

307 Fault screen. Select if device to Trigger on High. Select action on pull-

down menu to give a Warning, Start Downslope or Stop the Weld when fault

is detected. Type in device name from the keyboard.

AUXILIARY PLUG

FOOT CONTROL/

FOOT SWITCH

DATA RS 232

PENDANT

Type in

device

name from

keyboard

O2 Analyzer

or other

device

Streaming

Data

307-RP

Select

action from

pull-down

menu

Advertising