P O W E R R E Q U I R E M E N T S

Locations Using 50 Hz Power (Locations Other than North America and Japan)

Version 5

Model 200i and 250i Motorcycle Dynamometer Installation Guide

B-9

T

ESTING

FOR

C

ORRECT

V

OLTAGES

You must test the receptacle for proper voltages before the dyno is connected to the
outlet.
Using a voltmeter that is capable of measuring AC voltage, measure between the
points listed below and verify that the correct voltages are present.

Figure B-3: Test the Wall Receptacle

probe 1

probe 2

desired voltage measurement

1

3

220V to 250V

2

box

<5V

1

2

3