E D D Y C U R R E N T B R A K E I N S T A L L A T I O N

Eddy Current Brake Installation

Version 8

Above Ground Model 424x/424xLC

2

Automotive Dynamometer Installation Guide

4-13

I

NSTALLING

THE

L

OAD

C

ELL

You will need the following part:

• 76950505

Load Cell Assembly

1

Verify the main dyno power is disconnected.

2

Remove the two bolts and nuts securing the existing bar on the eddy current
brake and remove the bar. Set the bolts and nuts aside.

3

Verify the eyelets on the load cell are spaced the same as the bar removed earlier.
Adjust the load cell spacing by loosening the lock nut and turning the eyelet.

Figure 4-13: Verify Load Cell Spacing

4

Secure the load cell to the mounting bracket using the two bolts and nuts
removed earlier.

Figure 4-14: Install the Load Cell

distance must be

the same

eyelet

bar

lock nut

TM057

install the load cell

(the brake is not

shown for clarity)

load cell cable

dyno

Advertising