4 W D D Y N O I N S T A L L A T I O N

Bridge Installation—Stationary Dyno

Version 8

Above Ground Model 424x/424xLC

2

Automotive Dynamometer Installation Guide

3-37

I

NSTALLING

THE

R

UNNER

A

SSEMBLIES

1

Place the plastic runner slide on top of the runner support.

2

Slide each runner assembly into the runner mount. Verify the plastic end faces
away from the stationary dyno.

3

Loosely secure each runner assembly to the runner mount using one 3/8 x 5-inch
bolt, flat washer, lock washer, and nut. These bolts will be tightened later.

4

Loosely secure each runner assembly to the runner support from underneath
using one 1/4 x 1.25-inch bolt and lock washer. These bolts will be tightened later.
Verify the existing bolt in each runner assembly is on top. There are sixteen
runner assemblies, eight with each runner mount.
Note: For clarity, only one runner assembly is shown.

Figure 3-25: Install the Runner Assemblies

AD492

runner assembly

runner

mount

runner

assembly

runner support

existing bolt on top

secure from underneath

(not visible from this view)

plastic end

runner slide

Advertising