6 bios error messages, Bios error messages – Kontron TIGH2U Carrier Grade Server User Manual

Page 116

Advertising
background image

TIGH2U Server—Troubleshooting

Kontron Carrier Grade Server TIGH2U

Product Guide, rev.1.2,

December 2009

116

7.6

BIOS Error Messages

When a recoverable error occurs during the POST, the BIOS displays an error message describing the

problem. See

Table 15

Table 15.

BIOS Error Messages

Error Message

Explanation

GA20 Error

An error occurred with Gate A20 when switching to protected

mode during the memory test.

Pri Master HDD Error 

Pri Slave HDD Error 

Sec Master HDD Error

Sec Slave HDD Error

Could not read sector from corresponding drive.

Pri Master Drive - ATAPI Incompatible Pri

Slave Drive - ATAPI Incompatible Sec

Master Drive - ATAPI Incompatible Sec

Slave Drive - ATAPI Incompatible

Corresponding drive is not an ATAPI (Advanced Technology

Attachment Packet Interface) device. Run Setup to make sure

device is selected correctly.

CMOS Battery Low

The battery may be losing power. Replace the battery soon.

CMOS Display Type Wrong

The display type is different from what has been stored in CMOS.

Check Setup to make sure type is correct.

CMOS Checksum Bad

The CMOS checksum is incorrect. CMOS memory may have been

corrupted. Run Setup to reset values.

CMOS Settings Wrong

CMOS values are not the same as the last boot. Either these values

have been corrupted or the battery has failed.

CMOS Date/Time Not Set

The time and/or date values stored in CMOS are invalid. Run Setup

to set correct values.

DMA Error

Error during read/write test of DMA (Direct Memory Access)

controller.

FDC Failure

Error occurred trying to access diskette drive controller.

HDC Failure

Error occurred trying to access hard disk controller.

Checking NVRAM.....

NVRAM (Non-Volatile Random Access Memory) is being checked to

see if it is valid.

Update OK!

NVRAM was invalid and has been updated.

Updated Failed

NVRAM was invalid but was unable to be updated.

Keyboard Error

Error in the keyboard connection. Make sure keyboard is

connected properly.

KB/Interface Error

Keyboard interface test failed.

Memory Size Decreased

Memory size has decreased since the last boot. If no memory was

removed, then memory may be bad.

Memory Size Increased

Memory size has increased since the last boot. If no memory was

added, there may be a problem with the system.

Memory Size Changed

Memory size has changed since the last boot. If no memory was

added or removed, then memory may be bad.

No Boot Device Available

System did not find a device to boot.

Off Board Parity Error

A parity error occurred on an off-board card. This error is followed

by an address.

On Board Parity Error

A parity error occurred in onboard memory. This error is followed

by an address.

Parity Error

A parity error occurred in onboard memory at an unknown

address.

NVRAM / CMOS / PASSWORD cleared by

Jumper

NVRAM, CMOS, and passwords have been cleared. The system

should be powered down and the jumper removed.

<CTRL_N> Pressed

CMOS is ignored and NVRAM is cleared. User must enter Setup.