2 installing the remote management module 2, 5 installing an embedded usb solid-state drive, Installing the remote management module 2 – Kontron TIGH2U Carrier Grade Server User Manual

Page 62: Installing an embedded usb solid-state drive, Figure 42, Section 4.4.2, “installing the remote management

Advertising
background image

TIGH2U Server—Optional Component Installations

Kontron Carrier Grade Server TIGH2U

Product Guide, rev.1.2

December 2009

62

4.4.2

Installing the Remote Management Module 2

Note:

These steps assume you have just finished installing the RMM2 NIC module.

1. Insert the standoff into the T5000PAL server board. (

Figure 42

, “A”)

2. Fasten the RMM2 to the RMM connector on the server (“B”) and press it over the standoffs. (“A”)

Figure 42.

Installing the Remote Management Module 2

C

D

RMM2 NIC

Intel RMM2

A

B

TS000428

3. If this is the last task you are performing, install any other components you removed.

— For instructions to replace the PCI riser assembly, see

Section 4.2.5, “Installing the PCI Riser

Card Assembly” on page 59

.

— For instructions to replace the top cover, see

Section 3.2.4, “Installing the Chassis Cover” on

page 27

.

4.5

Installing an Embedded USB Solid-State Drive

The optional SMART Embedded USB Solid-State Drive (eUSB SSD) provides internal storage for OEM

applications. It is used with the SAS front panel (SFP) board to provide local memory storage for

options such as system information, diagnostic partitions, and configuration data. The eUSB SSD is

installed onto the TAM board. Before you install this component, you must remove the chassis top

cover and the processor air duct.

1. Remove the chassis top cover. For instructions, see

Section 3.2.3, “Removing the Chassis Cover”

on page 26

.

Advertising