3 installing dimms, Installing dimms – Kontron TIGH2U Carrier Grade Server User Manual

Page 44

Advertising
background image

TIGH2U Server—Server Component Installations and Upgrades

Kontron Carrier Grade Server TIGH2U

Product Guide, rev.1.2

December 2009

44

• DIMM D1 and DIMM D2 need not be identical in organization, size and speed.
• Sparing should be enabled in BIOS setup. The BIOS configures Rank Sparing Mode.
• The larger of the pairs {DIMM A1, DIMM B1}, {DIMM A2, DIMM B2}, {DIMM C1, DIMM D1} and

{DIMM C2, DIMM D2} will be selected as the spare pair units.

3.4.3

Installing DIMMs

To reduce the risk of electrostatic discharge (ESD) damage to the processor:

• Touch the metal chassis before touching the DIMM or server board.
• Keep part of your body in contact with the metal chassis to dissipate the static charge while

handling the DIMM.

• Avoid unnecessary movement.
• Use a ground strap attached to the front panel (with the bezel removed.)

To install DIMMs, follow these steps:

1. Remove the chassis cover. For instructions, see

Section 3.2.3, “Removing the Chassis Cover” on

page 26

.

2. Remove the processor air duct. For instructions, see

Section 3.2.5, “Removing the Processor Air

Duct” on page 28

.

3. Locate the DIMM sockets on the server board. (See

Figure 26

.)

4. Open both DIMM socket levers. (“A”)
5. Note the location of the alignment notch. (“B”)
6. Insert the DIMM making sure the connector edge of the DIMM aligns correctly with the socket.

(“E”)

7. Using both hands, push down firmly and evenly on both sides of the DIMM until it snaps into place

and the levers close. (“C” and “D”)
IMPORTANT: Visually check that each latch is fully closed and correctly engaged with notch on the

DIMM edge. (“E”)

8. Replace the air duct and chassis cover if you have completed all work inside of the server.

Advertising