Kontron TIGH2U Carrier Grade Server User Manual

Page 17

Advertising
background image

Kontron Carrier Grade Server TIGH2U

December 2009

Product Guide, rev.1.2

17

Features—TIGH2U Server

Figure 6

shows the control panel.

Figure 6.

Control Panel

Alarms

Status

ID

ON

NIC

CRT

MNR

PWR

MJR

A

B

E

F

G

H

C

D

I

J

K

L

TS000347

Item

Feature

Description

Front Panel Switches

A

Power switch

Toggles the system power

B

Reset switch

Resets the system

C

NMI switch (pin hole)

Asserts NMI to the server board

D

ID switch

Toggles the system ID LED on / off

Front Panel Alarm LEDs and Relays

E

Critical (amber or red)

The Critical alarm LED can be either amber (default) or red (set with an

FRUSDR update). When continuously lit, indicates a Critical System Fault

occurred. A critical system fault is an error or event that has a fatal

system impact. In this case, the system cannot continue to operate. An

example is the loss of a large section of memory, or other corruption. The

front panel critical alarm relay is engaged.

F

Major (amber or red)

The Major alarm LED can be either amber (default) or red (set with an

FRUSDR update). When continuously lit, indicates a Major System Fault

occurred. A major system fault is an error or event that has discernible

impact to the system operation. In this case, the system can continue to

operate, but in a degraded fashion (reduce performance or with the loss

of non-fatal features). An example is the loss of a mirrored disk. The front

panel major alarm relay is engaged.

G

Minor (amber)

When continuously lit, indicates a Minor System Fault occurred. A minor

system fault typically has little impact to the system operation. An

example is a correctable ECC error. The front panel minor alarm relay is

engaged.

H

Power (amber)

When continuously lit, indicates a Power System Fault occurred. The front

panel power alarm relay is engaged.

Front Panel Status LEDs

I

System ID LED (white)

Indicates system identity
This LED can be toggled remotely or by front panel ID switch

J

NIC activity LED (green)

Indicates NIC activity when lit

K

Main power LED (green)

When continuously lit, indicates the presence of power supply DC output

power in the server. The LED turns off when the main output power from

the power supply is turned off or if the power source is disrupted.

L

HDD activity / fault LED

(green / amber)

Indicates HDD activity when green or an HDD fault when amber. This is an

aggregated indication for all hard drives in the system (up to six). Each

hard disk contains its own activity and fault indicators.

Advertising