Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 2.3 User Manual

Page 35

Advertising
background image

Counterpart User Manual - Configuration

29

FEATUR Menu

Parameter

Choices

Description

Level 3 submenus - Feature

COUNT

NEGCOUNT
SAMPLEQTY
INSFSMPL
LOTUPDT
SCLCHG
NEWITEM
DISPACC

UNITWTUPDATE

UTWTBASE
TareWTUpDate

Selects the counting mode (enables/disables negative checkweighing; turns data parameters
on/off. See Level 3 submenus.

REGION

REGULA
REGWRD
DECFMT
TIME
DATE

Selects regional settings. See Level 3 submenus.

UID

1

Sets the unit ID, a string of up to 6 ASCII characters, which can be set via serial port or
keypad. This will be used in place of the <UID> token in a print format. The default value is “1.”

CONSC#

CURVAL
RESVAL

Allows sequential numbering for print operations (CURVAL is the current value and RESVAL is
the reset value). The consecutive number value is incremented following each print operation
that includes <CN> in the ticket format. When the consecutive number is reset, it is reset to
the RESVAL specified on the parameter.

PASSWD

CALIBR
SETUP
TEST
T&D
ID

Creates a password to access the CALIBR, SETUP, TEST, T&D, and ID menus. Specify a
non-zero value to restrict access to all configuration menus. Passwords can be overridden by
loading new firmware or entering 999999.

Note

Overriding passwords will clear configuration and calibration settings. To
preserve settings (i.e., ID information), use Revolution software to upload
your data to a PC, then download it back to the indicator after the

password override is performed.

SOFTKEYS

SK1-12

KEYLCK

MENU
ZERO
GRSNET
UNITS
PRINT
TARE
NUMBER
SAMPLE
UNIT WT

Disables the MENU, ZERO, GROSS/NET, UNITS, PRINT, TARE numeric, SAMPLE and UNIT
WEIGHT keys. Select LOCK to disable the key, and UNLOCK to enable the key.

STNDBY

0

Standby mode delay. Specifies the number of minutes the indicator must be inactive before
entering standby mode. Valid values are 0 (off) through 255 minutes. When in standby mode,
power is still supplied to the CPU and draws half of the current as when the display is
powered. The display is no longer updated and the backlight is off. Press any key to exit
standby mode and reactivate the display.The indicator enters standby mode if no key presses,
serial communications, or scale motion occur for the length of time specified in this parameter.
Set to 0 to disable standby mode.

Note

If regulatory agency is set for NONE or INDUST, the standby will occur
after the specified number of minutes regardless of how much weight is on
any of the scales. If regulatory agency is set for NTEP, OIML, or Canada a

standby will only occur when the weight on the currently viewed scale is at center of
zero.

Table 3-5. FEATUR Submenu Parameters

Advertising