Counterpart User Manual

6.1.2

ID Commands

Up to 150 codes can be entered under ID commands.

Command

Function

ID.CODE#n

ID code

ID.DESC#n

item description

ID.LOCATION#n

item stock location

ID.LOT#n

lot number

ID.PARTNUMBER#n

part number

ID.QUANTITY#n

inventory quantity

ID.TARE#n

tare weight value

ID.UNITS#n

units for tare and unit weight values

ID.UNITWEIGHT#n

unit weight value

ID.CLRALL

clear all IDs from memory

Note: The ID.CLRALL command only
works in setup mode

ID.CLEAR.INDEX#n

clear ID at index n from memory

ID.CLEAR.CODE#n

clear ID with code of n from memory

Table 6-2. ID Commands

6.1.3

Reporting Commands

Reporting commands send specific information to the
serial port. The commands listed in Table 6-3 can be
used in all modes.

Table 6-3. Reporting Commands

Command

Function

DUMPALL

List all parameter values, ID information
and setpoint data

DUMPCONFIG

List all parameter values excluding ID
information and setpoint data

DUMPAUDIT

List audit trail information

DUMPBUFFER

Lists Weighvault buffer information

DUMPIDS

List all ID information

DUMPID.INDEX

List a specific ID by index. See table 6-13
for more information.

DUMPIDCODE

List a specific ID by code. See table 6-13
for more information.

VERSION

Write

Counterpart

software version

P

Write current displayed weight with units
identifier. See Section 9.2.1 on page 79.

XE

Returns a 10-digit code representing any
error conditions currently shown on the
front panel.

ADCS

Return number of A/Ds installed

Note

Transmitting all configuration settings can be
achieved by the DUMPALL command

6.1.4

Clear and Reset Commands

The following commands can be used to clear and
reset the

Counterpart

:

RS

: Reset system. Resets the indicator without

resetting the configuration.

RESETCONFIGURATION

: Restores all

configuration parameters to their default values
(menu mode only). The

RESETCONFIGURATION

function can also be initiated by pre ssing
navigating to the

DEFALT

parameter under the

VERS menu and selecting YES. Then press

ENTER

to reset the indicator.

Note

All load cell calibration settings are lost
w h e n t h e R E S E T C O N F I G U R AT I O N
command is run.

CLEARBUFFER

: Clears the Weighvault data buffer.