Counterpart User Manual - Configuration

41

Level 3 Submenu

SP CFG

SETPT 1
SETPT 2-6

Specifies the settings for gross,net, piece count, % rel, delay, waitss, counter and
inmotion used by setpoints 1 through 6.

BATCHING

OFF
AUTO
MANUAL

Batching enable. Set to AUTO or MANUAL to allow a batch sequence to run. MANUAL
requires a Batch Start softkey before the batch sequence can run. AUTO allows batch
sequences to repeat continuously.

Level 4 Submenu

SETPT1

OFF
GROSS
NET
PIECECNT
%REL
DELAY
WAITSS
COUNTER
INMOTION

Specifies the setpoint kind.
GROSS, NET, PIECECNT, and %REL setpoint kinds can be used as either batch or
continuous setpoints. DELAY, WAITSS, and COUNTER setpoint kinds can only be used in
batch sequences.
The INMOTION setpoint kind can only be used as a continuous setpoint.

SETPT 2-6

SAME AS
SETPT 1

Level 5 Submenu

OFF

Value=number

GROSS
NET
PIECECNT
%REL

Value
Source
Trip
Bandval
Hyster
Preact
Preval
Preadj
Prestab
Pcount
Relnum
Batch
Pshaccm
Pshprint
Pshtare
Access
Digout
Sense

Display and edit the gross value

DELAY

Value
Source
Pshaccm
Pshprint
Pshtare
Access
Digout
Sense

Table 3-8. Setpoints Menu Parameters