Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 2.3 User Manual

Page 72

Advertising
background image

66

Counterpart User Manual

SC.WLIN.V1
SC.WLIN.V5#n

Test weight value for linearization points
1–5

0.000001–9999999

SC.WLIN.C1–
SC.WLIN.C5#n

Calibrate linearization points 1–5

SC.LC.CD#n

Deadload coefficient

SC.LC.CW#n

Span coefficient

SC.LC.CZ#n

Temporary zero

SC.REZERO#n

Rezero

SC.SEC#n

Secondary units

lb, kg, g, oz, OFF

SC.TER#n

Tertiary units

lb, kg, g, oz, OFF

Command

Description

Values

Table 6-4. SCALES Serial Commands (Continued)

Command

Description

Values

EDP.BAUD#p

Port baud rate

1200, 2400, 4800, 9600, 19200, 28800, 38400, 57600, 115200

EDP.BITS#p

Port data bits/parity

8NONE, 7EVEN, 7ODD

EDP.STOPBITS#p

Port stop bits

1, 2

EDP.PRNMSG#p

Print message

ON, OFF

EDP.ECHO#p

Port echo

ON, OFF

EDP.EOLDLY#p

Port end-of-line delay

0–255 (0.1-second intervals)

EDP.HEADERS#p

Port header

ON, OFF

EDP.INPUT#p

Port input

PORT 1 - CMD, SCANNER, SCALE, IND SC
PORT 2 - CMD, SCANNER
PORT 3 - CMD, SCANNER, KEYBOARD

EDP.PORT

Port reporting command. It responds to the port you are connected to.

EDP.RESPONSE#p

Port response

ON, OFF

EDP.SOURCE#p

Port source

1, 2, 3

EDP.STREAM#p

Port stream

OFF, LFT, INDUST

EDP.TERMIN#p

Port termination

CR/LF, CR

STR.POS#p

Custom stream identifiers

None, Space, +

STR.NEG#p

None, Space, -

STR.PRI#p

8 alphanumeric characters

STR.SEC#p

STR.TER#p

STR.GROSS#p

STR.NET#p

STR.TARE#p

STR.MOTION#p

2 alphanumeric characters

STR.RANGE#p

STR.OK#p

STR.INVALID#p

STR.ZERO#p

Table 6-5. SERIAL Port Serial Commands