5 ids, 1 setting an id using the normal mode, Setting an id using the normal mode – Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 2.3 User Manual

Page 61: Key after removing each batch of pieces, Press the

Advertising
background image

Counterpart User Manual - Scale Operations

55

Counting Out of a Full Container - See Total Amount Remaining in the Container

To carry out this operation you must know the tare weight ahead of time.

1. Place the full container on the scale. Press the

TARE

key.

2. Remove a 10 piece sample to the container and press the

SAMPLE

key. After the unit weight has been

calculated, return the 10 piece sample to the container.

3. If you want to see how many are still in the bin you first have to know the tare weight of the bin or

container. After removing the parts you want to take out of the bin, simply digitally enter the tare weight
of the bin and press the

TARE

key. The scale will display how many parts were left in the bin. To print a

label to put on the bin showing the total quantity in the bin, press the

PRINT

key.

Negative Counting - Total Removed Displayed at the End

With this procedure you can count accurately out of a full container for kitting, shipping, etc.without having to
know the tare weight of the container.

1. Place a full container on the scale and press

TARE

.

2. Remove a 10 piece sample from the container and press

SAMPLE

. After the unit weight has been

calculated, return the 10 piece sample to the container.

3. Remove the number of pieces you need for kitting, shipping, etc. The amount removed will be displayed.

If you need a label for each kit or container, press the

PRINT

key after removing each batch of pieces.

5.5

IDs

IDs are used to save and recall previously set codes, descriptions, unit weight, and tare preferences. The

Counterpart

has the capacity to store up to 150 individual IDs. There are three ways that IDs can be entered and

set. Those three ways include:

1. Normal

2. Through Count Mode

3. Through Revolution

To enter alpha ID characters you can double press the numeric keypad to obtain alpha characters much like
accessing alpha characters on a cell phone keypad.

To store more than 150 IDs, WeighVault is required (see Section 5.6 on page 58).

REG 1

REG 2

QUANTITY

SAME AS REG 1

CODE

DESC

PART NUM

LOT

UNIT WT

TARE

VALUE

VALUE

VALUE

LB

G

KG

OZ

OFF

UNITS

LOCATION

XXXXXXX

ID

DISPLAY

TEST

SETUP

AUDIT

CALIBR

REG 150

SAME AS REG 1

VALUE

VALUE

VALUE

VALUE

VALUE

SETPTS

Figure 5-1. ID Menu

5.5.1

Setting an ID Using the Normal Mode

1. Press the

MENU SETUP

key

MENU

SETUP

to access this menu.

2. Press to ID and then press

and you will be at REG1.

3. Navigate to the REG number you want to set (1-150) by using the and keys.

Note

All menus have wrap-around functionality. If you are at ID1 and want to access ID150, you can quickly do so
by moving backwards through the menu.

Advertising