Counterpart User Manual - Configuration

43

BATCH

Off
On

Specifies whether the setpoint is used as a batch (ON) or continuous (OFF) setpoint.

PSHACCM

Off
On
ONquiet

Specifiy ON to update the accumulator and perform a print operatoin when the setpoint is
satisfied. Specify ONQUIET to update the accumulator without printing.

PSHPRNT

Off
On
Waitss

Specify ON to perform a print operation when the setpoint is satisfied; specify WAITSS to
wait for standstill after setpoint is satisfied before printing.

PSHTARE

Off
On

Specify ON to perform an acquire tare operation when the setpoint is satisfied. Note that
PSHTARE acquires the tare regardless of the value specified for the REGULAT parameter
on the FEATURE menu.

ACCESS

On
Hide
Off

Specifies the access allowed to setpoing parameters shown by pressing the Setpoint
softkey in normal mode.
ON: Values can be displayed and changed.
HIDE: Values cannot be displayed or changed.
OFF: Values can be displayed but not changed.

DIGOUT

None
1-4

Lists all digital output bits available. This parameter is used to specify the digital output bit
associated with this setpoint. Use the DIGI/O menu to assign bit function to OUTPUT. For
continuous setpoints, the digital output becomes active (low) when the condition is met;
for batch setpoints, the digital output is active until the setpoint condition is met.

SENSE

Normal
Invert

Specifies whether the value of the digital output associated with this setpoint is inverted
when the setpoint is satisified.

Table 3-8. Setpoints Menu Parameters