Counterpart User Manual - Serial Commands

69

6.1.6

Normal Mode Commands

The normal mode print commands (see Table 6-12) transmit data to the serial port on demand in either setup or
normal mode.

Table 6-12. Normal Mode Serial Commands

Command

Description

Values

CONSNUM#n

Set consecutive number

nnnnnnn

UID

Set unit ID

UID=nnnnnnn

SX#n

Start serial port streaming

OK or ??
An EX command sent while in menu mode does not take effect until the
indicator is returned to normal mode.
The EDP.Stream must be set to LFT or INDUST for this command to work.

EX#n

Stop serial port streaming

XG#n

Transmit gross weight in displayed units

nnnnnn UU

where nnnnnn is the weight value, UU is the units.
NOTE: You can also send XGP, XGS, XGT, XTP, etc. to specify primary,
secondary or tertiary (P.S.T.).

XN#n

Transmit net weight in displayed units

XT#n

Transmit tare weight in displayed units

XA#n

Transmit accumulator value

RS

Reset system

Soft reset. Used to reset the indicator without resetting the configuration to the
factory defaults.

SD

Set date

SD=MMDDYY, DDMMYY, YYMMDD, or YYDDMM. Enter six-digit date using
the year-month-day order specified for the DATEFMT parameter, using only the
last two digits of the year.

ST

Set time

ST=hhmm (enter using 24-hour format)

KSOFT1-4

Command to perform function assigned
to softkey.

n/a

PIECES#n

Transmits data from the scale

n/a

6.1.7

Unique Commands

Table 6-13. Unique Commands

Command

Description

DUMPID.INDEX=n

To dump an ID by register

DUMPID.CODE=n

To dump an ID by code

KDISPMODE

Set or request the current display mode. KDISP=COUNT. Will switch to that mode. This only temporariliy
switches display. Default is set by dispmode parameter.
Other choices include:
COUNT
WEIGHT
UNIT WEIGHT