SETUP SELECT MENU

1 Function Keys

2 Set Points

3 System

4 Password Locks

5 BarCode

6 Total

7 MORE 1/2

PRODUCT ID Chan X-X

Net XX ID IDName--

1 New Product ID

2 ID Units kg

3 Edit ID Strings

4 Edit ID Name

5 Display Mode NORM

CLR Delete ID(s)

SETUP SELECT MENU

1 Channel & Calibrate

2 Scale Display Line

3 RF Modem

4 Comm 2 & Strings

5 Product ID Codes

6 Tare

7 MORE 2/2

Shortcut

Len 0 F4 Menu

Max 8 ENT Save

Pos 1

Prod ID Name

PRODUCT ID Chan X-X

Net XX ID IDName--

1 Edit ID String 1

-ID String 1-

2 Copy prev String 1

3 Edit ID String 2

-ID String 2-

4 Copy prev String 2

2 ID Units kg

Len 0 F4 Menu

Max 20 ENT Save

Pos 1

ID String 1

2 ID Units lb

Steps through available units

(defined at CellScale)

1

1

Delete This ID

Are You Sure?

ENTER = Yes, Delete

ESC = No, Cancel

CLR = Delete All IDs

Delete All IDs

Are You Sure?

Deletes all Totals,

Stats,Names,Strings

ENTER = Delete All

ESC = No, Cancel

5 Display Mode NORM

5 Display Mode %

5 Display Mode OFF

SETUP SELECT MENU

SETUP SELECT MENU

PRODUCT ID Chan

X-X

ZERO

CLR

0

ZERO

CLR

0

ESC

!

SETUP

ESC

!

SETUP

ID

F6

PRODUCT ID CODES

SETUP SELECT MENU

1 Function Keys

2 Set Points

3 System

4 Password Locks

5 Bar Code

6 Total

7 MORE 1/2

BAR CODE SETUP MENU

1 Bar Code 1 Buffer

2 Bar Code 2 Buffer

3 Bar Code 3 Buffer

4 Bar Code 4 Buffer

5 User Str Buffer

6 User Str Buffer

7 Auto Save Serial

BAR CODE X IS SENT TO

1 CellScale Comm 1

2 All CS Outputs

3 CS RF Host 3

4 CS RF Host 4

5 CS RF Host 5

6 9750 Printer Port

7 String Buffer Only

Usr StrX IS SENT TO

1 CellScale Comm 1

2 All CS Outputs

3 CS RF Host 3

4 CS RF Host 4

5 CS RF Host 5

6 9750 Printer Port

7 String Buffer Only

7 Auto Start BC1 OFF

7 Auto Start BC1 ON

1 Bar Code 1

XX

Chars

2 Bar Code 2

XX Chars

3 Bar Code 3

OFF

4 Bar Code 4

OFF

5 Usr Str 1

OFF

6 Usr Str 2

OFF

7 AutoStart BC 1

OFF

AUTO CHARS BARCODE

1

ESC exits no change

ENTER saves value

0-9 insert

min = 0, max = 64

^ incs, v decs digit

SETUP SELECT MENU

BAR CODE SETUP MENU

BAR CODE

X

IS SENT TO

USER STR

X

IS SENT TO

MINIMUM STRING SIZE

AUTO CHARS BARCODE

X

1

ESC

!

SETUP

5

MNO

2

DEF

1

ABC

3

GHI

6

PQR

5

MNO

4

JKL

7

STU

1-6

7

STU

BAR CODE SETUP

Go to Index

Advertising