Keyboard lock, Lc display backlight & contrast – Rice Lake MSI-9850 CellScale RF Digital Indicator - Operator Manual User Manual

Page 55

Advertising
background image

MSI CellScale

®

System • 9850 User Guide Page 55

MEASUREMENT SYSTEMS INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

KEYBOARD LOCK

Keyboard lock is provided to prevent casual or accidental pressing of the keys from changing any modes. This

function works only from weight display modes.

1) Press

POWER

followed immediately by

ESC

(

SETUP

). The startup screen will appear.

2) Press the

CLR

(

ZERO

) key. A password text entry screen will appear.

3) Using the keypad, input the number 7415369. Press

ENTER

.

4) The “ARE YOU SURE” display appears. Press

ENTER

.

Everything is reverted to defaults. Now you must setup the 9850 again.

RESET ALL: The following procedure will cause you to lose all setups and will return

the 9850 to it’s default settings. Use this procedure only as the last resort of having lost

your password.

To Lock the Keyboard

Press

[1] [2] [3]

ALPHA

. The screen will read “KEYBOARD LOCKED” briefly.

While in Keylock mode, pressing any key will show the screen “KEYLOCK PUSH 123””

To Unlock the Keyboard

Press

[1] [2] [3]

. The screen will read “KEYBOARD UNLOCKED” briefly.

Now all keys should function normally.

SCALE DISPLAY SETUP

1 Single Scale Mode

2 Multi Scale Mode

3 Backlight

2min

4 Backlight Level

3

5 Contrast

10

BACKLIGHT

1 Off (max batt-life)

2 On for 15 seconds

3 On for 30 seconds

4 On for 1 minute

5 On for 2 minutes

6 On (min batt-life)

7 Light on Motion OFF

7 Light on Motion OFF

7 Light on Motion ON

SCALE DISPLAY SETUP

Shortcut

BACKLIGHT

BACKLIGHT BRIGHTNESS

ESC exits no change

ENTER edits value

0-9 replaces value

2

min = Ø, max = 3

^ incs, v decs value

BACKLIGHT BRIGHTNESS

BACKLIGHT BRIGHTNESS

ESC exits no change

ENTER edits value

0-9 replaces value

min = Ø, max = 3

^ incs, v decs value

DISPLAY CONTRAST

ESC

!

SETUP

DISPLAY

EXIT

7

STU

4

JKL

5

MNO

LC DISPLAY BACKLIGHT & CONTRAST

The 9850 features a white LED Backlit Liquid Crystal Display. The LED Backlight is one of the highest power

drain devices in the 9850. The Backlight can be set to turn itself off automatically after a user sepcified time.

Once off, the Backlight will turn back on by pushing any key (except

POWER

). The first key press, no matter

which key it is, will be ignored, except for turning the Backlight on. Then key function is restored. The Backlight

can also be set to turn back on when the active channel scale changes its reading (goes in motion). There are 3

levels of brightness with a setting of 0 being another way to turn it off. AC or DC supply powered 9850’s can

and should choose to leave the backlight on at full (3) brightness. In battery powered units, battery life can be

extended through the use of the power down modes and reduced brightness settings.

1) Press

SETUP

,

DISPLAY

,

[3]

. The BACKLIGHT menu

appears. Select the desired on time from 2-6. Off (1) is

usually not desired as this is a transmissive display and has

poor contrast without a backlight. On AC Powered units,

choice 6, always on, is the preferred choice.

2) Press

[7]

to change the Light on Motion setting from OFF

to ON. When ON, the backlight will turn back on whenever

the current scale channel changes its reading. However set-

ting Light on Motion On may prevent the backlight from

ever turning off, thus decreasing battery life in battery

powered units.

3) Press

ESC

to backup to the SCALE DISPLAY SETUP

menu. Press

[4]

to change the backlight brightness level.

A setting of 0 turns off the backlight. 4 is the brightest. Set

the brightness level as low as is useful in your environment.

Press

ENTER

to set your brightness choice.

Setting the LCD Backlight