Ection, 8 – 9850 s, Etup – Rice Lake MSI-9850 CellScale RF Digital Indicator - Operator Manual User Manual

Page 53: System setup menu

Advertising
background image

MSI CellScale

®

System • 9850 User Guide Page 53

MEASUREMENT SYSTEMS INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

5 Daylite Saving OFF

5 Daylite Saving ON

SYSTEM SETTINGS

CS SW Version: 2-24

1 Key Volume is 1

2 Alarm Volume is 9

3 Backlight on 2min

4 Date & Time

5 Auto Shutdown 2hr

6 Monitor Batteries

BACKLIGHT

1 Off (max bat-life)

2 On for 15 seconds

3 On for 30 seconds

4 On for 1 minute

5 On for 2 minutes

6 On (min batt-life)

7 Light on Motion OFF

SET DATE & TIME

9/15/03 1:24:33 PM

1 Set Date

2 Set Time

3 Date Mode MM/DD/YY

4 Time Mode AM/PM

5 Daylite Saving ON

4 Time Mode 24 Hr

4 Time Mode AM/PM

3 Date Mode DD-MM-YY

3 Date Mode MM/DD/YY

5 DayliteSaving AUTO

AUTOMATIC SHUTDOWN

1 Off in 5 minutes

2 Off in 30 minutes

3 Off in 1 hour

4 Off in 2 hours

5 Always On

MONITOR BATTERIES

Main = 7.2V

Clock & RAM = GOOD

CellScale XX = GOOD

Cal. Voltage = 1.24V

Temperature is 33°C

Shortcut to Battery Monitor

KEYPRESS VOLUME = 1

1 z

2 n

3 nz

4 nn

8 nnnn

5 nnz

9 nnnnz

6 nnn

0 nnnnn

7 nnnz

CLR Off

ALARM VOLUME = 8

1 z

2 n

3 nz

4 nn

8 nnnn

5 nnz

9 nnnnz

6 nnn

0 nnnnn

7 nnnz

CLR Off

SETUP SELECT MENU

1 Function Keys

2 Set Points

3 System

4 Password Locks

5 Display Preview

6 Total

7 MORE 1/2

SETUP SELECT MENU

SYSTEM SETTINGS

KEYPRESS VOLUME = 1

5

MNO

5

MNO

ALARM VOLUME = 8

BACKLIGHT

SET DATE & TIME

AUTOMATIC SHUTDOWN

MONITOR BATTERIES

ESC

!

SETUP

POWER

4

JKL

ESC

!

SETUP

3

GHI

4

JKL

3

GHI

2

DEF

1

ABC

6

PQR

3

GHI

SECTION 8 – 9850 SETUP

SYSTEM SETUP MENU

Allows the user to set the key and alarm volumes, the display back-

light timing, the Time and Date, and the automatic shutdown timing.

The battery monitor screen is also accessible from this menu.

Access the System Setup Menu by pressing

SYSTEM

followed

by the

[3]

key.

[1]

Key Volume is X – In the submenu, change the volume

heard when pressing keys with keypad numbers 1 (quiet)

through 0 (loud). To turn off the key tones, press

CLR

.

[2]

Alarm Volume is X – Change the volume heard when a

set point is triggered. Also used for data logging alerts.

See

section 8 for details on audible set point outputs.

[3]

Backlight on X – Submenu selects how long the backlight

will remain on. This value is re triggered whenever a key

is pressed. Directly effects battery life (time between

charges). Do not select “Always On” if battery life is a

concern.

[4]

Date & Time – See submenu description below.

[5]

Auto Shutdown – Select the time the 9850 will wait before

turning off. This time is re triggered any time a key is

pressed.

[6]

Monitor Batteries – The monitor battery screen shows the

status of system batteries. The NiMH main battery will

vary from as high as 9.0V with the charger plugged in to

as low as 6.0V right before the system is cut off. The flat

region of the battery will average 7.4 to 7.6V during normal

operation. The internal clock battery should last for many

years. When this display indicates “BAD” for the clock

battery, it must be replaced. This requires a disassembly

of the 9850. If a CellScale is connected via RF, it will also

report its power status here.

A shortcut to the Monitor Batteries screen is

SETUP

fol-

lowed by

POWER

.

SET DATE & TIME (submenu)

The Real Time Clock / Calendar is not synchronized with the CellScale. Both loca-
tions must be set independently.

From the “System Setup Menu” select

4

.

[1]

Set Date – Enter the date with the numeric keypad. The

date entry order is set by item 3.

[2]

Set Time – Enter the current time with the keypad. The

time entry mode is set by item 4. When in AM/PM mode

use either the

UP

/

DOWN

cursor keys to change AM to

PM or PM to AM, or use the

ABC1

key for AM or the

PQR6

key for PM.

To prevent the 9850 from adding or subtracting an hour, set the daylight saving
mode before setting the date and time.

Go to Index

Advertising
This manual is related to the following products: