MSI CellScale

®

System • 9850 User Guide Page 89

MEASUREMENT SYSTEMS INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

SETUP SELECT MENU

1 Function Keys

2 Set Points

3 System

4 Password Locks

5 Bar Code

6 Total

7 MORE 1/2

BAR CODE SETUP MENU

1 Bar Code 1 Buffer

2 Bar Code 2 Buffer

3 Bar Code 3 Buffer

4 Bar Code 4 Buffer

5 User Str 1 Buffer

6 User Str 2 Buffer

7 Auto Save Serial

BAR CODE X IS SENT TO

1 CellScale Comm 1

2 All CS Outputs

3 CS RF Host 3

4 CS RF Host 4

5 CS RF Host 5

6 Comm Port 1

7 String Buffer Only

Usr StrX IS SENT TO

1 CellScale Comm 1

2 All CS Outputs

3 CS RF Host 3

4 CS RF Host 4

5 CS RF Host 5

6 9850 Comm Port 1

7 String Buffer Only

7 Auto Start BC1 OFF

7 Auto Start BC1 ON

1 Bar Code 1

XX

Chars

2 Bar Code 2

XX Chars

3 Bar Code 3

OFF

4 Bar Code 4

OFF

5 Usr Str 1

OFF

6 Usr Str 2

OFF

7 AutoStart BC 1

OFF

AUTO CHARS BARCODE

1

ESC exits no change

ENTER saves value

0-9 insert

min = 0, max = 64

^ incs, v decs digit

SETUP SELECT MENU

BAR CODE SETUP MENU

BAR CODE

X

IS SENT TO

USER STR

X

IS SENT TO

MINIMUM STRING SIZE

AUTO CHARS BARCODE

X

1

ESC

!

SETUP

5

MNO

2

DEF

1

ABC

3

GHI

6

PQR

5

MNO

4

JKL

7

STU

1-6

7

STU

To set up the Bar Code reader, press

SETUP

then

[5]

.

1) BarCode 1 – The sub-menu designates the output

mode when data comes in for Bar Code 1.

[1]

Select-

ing 1 will send the data to the master CellScale’s

Comm Port 1.

[2]

Bar Code 1 data will be sent to all

of the CellScales active ports, both direct connect, and

RF connected.

[3]

BC1 data is sent to the CellScale

RF Host 3.

[4]

BC1 data is sent to the CellScale RF

Host 4.

[5]

BC1 data is sent to the CellScale RF Host

5.

[6]

BC1 data is sent to the transmit line on the 9850

Comm Port.

[7]

No action, the Bar Code data is stored

in the Bar Code 1 buffer and is available for inclusion

in print strings or sent to the display.

2-4) BarCode 2-4 – Same options as above.

5) User String 1 – The title here will change if the User

String 1 function key was titled by the user. For

example it might read “Operator” indicating the User

String 1 is used to store an Operator ID. “Sent To”

options are the same as above.

6) User String 2 – The title here will change if the User

String 2 function key was titled by the user. For

example it might read “Customer” indicating the User

String 1 is used to store an Customer ID. “Sent To”

options are the same as above.

7) Auto Save Serial – Pressing

[7]

brings up the MINI-

MUM STRING SIZE menu. Used to designate the

minimum acceptable size of autoentered data. For

example; Suppose the operator ID stored in User

String 1 has to be 6 characters or more. By setting the

Auto Enter size to 6, a bar code or text entry that is

too small will not automatically enter into the desig-

nated string. The text entry screem will appear if the

input code is too small, allowing the user to reject the

data (press

ESC

), accept the data (press

ENTER

), or

append to the data with the alphanumeric keypad.

MINIMUM STRING SIZE MENU
1-4) Pressing 1-4 brings up a numeric entry screen that allows you to set the minimum string size of the four

available Bar Code Strings . Bar Code strings can be up to 64 characters in length.

5-6) Pressing 5 or 6 allows setting the minimum size of the ID User Strings. User Strings are limited to 20 char-

acters.

7) AutoStart BC 1 – Turning “Auto Start Bar Code 1” on will designate any data coming in the Comm Port,

while in the weight display mode, will automatically input into the Bar Code 1 buffer. This eliminates the

need to first push a function key to tell the 9850 where to put the data.