Set point formula menu – Rice Lake MSI-9850 CellScale RF Digital Indicator - Operator Manual User Manual

Page 71

Advertising
background image

MSI CellScale

®

System • 9850 User Guide Page 71

MEASUREMENT SYSTEMS INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

SET POINT FORMULA MENU

OPERATOR 1 SP XX

1 Greater Than >

2 > or Equal >=

3 Less Than <

4 < or Equal <=

5 Off

SET POINT VALUE 1

ESC exits no change

ENTER saves value

0-9 replaces value

500

min = 0, max =CAP

^ incs, v decs value

VALUE 1 TYPE

SP

XX

1 Gross

2 Net or Gross

3 Total

4 # of Totals

PREACT VALUE

ESC exits no change

ENTER saves value

0-9 replaces value

10

min = 0, max = CAP

^ incs, v decs value

4 Relationship OR

4 Relationship AND

4 Relationship NONE

VIEW FORMULA SP XX

Set Pt Triggers If

N/G Wt >= 500.0

AND N/G Wt <=1000.0

Set Pt Resets If

N/G Wt < 500.0

OR N/G Wt > 1000.0

PREACT VALUE

ESC exits no change

ENTER saves value

0-9 replaces value

10

min = 0, max = CAP

^ incs, v decs value

1, 2, & 3 menus are similar to Value 1 menus

VALUE 2 ENTRY SP XX

1 Operator 2

>

2 Value 2

XXXXXXX

3 Val 2 Type

GROSS

4 Relationship

to Value 1

AND

5 View Formula

5

MNO

4

JKL

6

PQR

7

STU

1

ABC

2

DEF

3

GHI

4

JKL

OPERATOR 1 SP

XX

SET POINT VALUE 1

VALUE 1 TYPE SP

XX

VALUE 2 ENTRY SP

XX

PREACT VALUE

or POSTACT

VIEW FORMULA SP

XX

DEADZONE VALUE

FORMULA SP XX

1 Operator 1

>

2 Value 1

XXXXXXX

3 Val 1 Type

GROSS

4 Dual Value

OFF

5 Preact

XXXXXXX

6 Deadzone

XXXXXXX

7 View Formula

FORMULA SP

XX

1) Operator 1 – Use the sub-menu to select the compare

operator. In dual value alarms, this operator only

applies to value 1.

2) Value 1 – Pressing

[2]

brings up a number entry

screen allowing the set point value entry.

Press the Alpha key to enter a negative number. The key will not

respond on value types other than Net or Gross weight.

3) Val 1 Type – This menu determines the weight type

the set point will use in compare. Use Gross

[1]

for overload alarms that should not change even if

the scale is in Net mode. Use “Net or Gross”

[2]

if the set point should be relative to Net or Gross

zero such as when weighing product for sale. Use

Total

[3]

for a set point that uses the current ID total

register value. Use “# of Totals”

[4]

for a set point

that responds to the number of total weighments.

Useful as a box counter or product counter.

4) Dual Value – Enabling dual value allows window

set points with upper and lower values. Use the

sub-menus to set the operator

[1]

, value

[2]

, weight

type

[3]

, and the Relationship

[4]

for value 2. There

are three relationship choices: AND, both set point

conditions must be true for the set point to trigger.

OR, if either set point condition is true the set point

triggers. NONE, Value 2 is ignored, only value 1 is

used.

5) Preact – Enters a value that subtracts from the base

set point value. To change this menu item to Postact

(adds to the base set point value) use the

[ALPHA]

key.

6) Deadzone – Enters a hysteretic value for the Set

point.

7) View Formula – Show the whole effect of all the

entries. N/G is used for Net/Gross Wt.

See the CellScale 9000 User Guide for a through explanation of Set Point operation
and how to control relays at the CellScale end.

Direct Relay Control
The 9850 provides direct remote relay control for remote

control operations, start-stop conditions, etc. This feature

uses either the Set Point output controls (which must be

set up in the CellScale), or the 9850 Relay Option.

The Set Point Formula Menu controls the compare values

and Set Point type selection.