MSI CellScale

®

System • 9850 User Guide Page 13

MEASUREMENT SYSTEMS INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

9850 P2

PWR PORT

Pin 1- Vin+

Pin 2 - SW1

Pin 3 - GND

Pin 4 - SW2

Pin 5 - LED

or

SW4

SW1

Aux Power, Remote Switches, Remote LED Connection

Aux Battery or

Power Supply

Power

Source

6-25Vdc

+

SW2

Momentary Switches Only

BRN

WHT

BLUE

BLK

GREY

Pin 6 - SW3

PINK

SW3

SW4

FOR LED

FOR SW4

or

LED

Silicon

Diode

Add Diode

to allow LED

and SW4

LED

Insulate all unused wires.

Green

Connect to Earth Ground.

The negative input and earth ground are isolated internally in the 9850. However, the negative output of the Isolated DC supply is common to the chassis ground. Some
systems may require isolating the chassis of the 9850 to avoid ground loops. In this case, the Green wire should be insulated and not connected to earth ground.

The 9850’s Isolated DC Supply is protected by an internal Fuse. Panel fusing, if necessary, shoud be 1.5A @12Vdc,

3/4A @ 24V, or 3/8A @ 48V. Due to power on surge currents, slightly increased fuse ratings might be needed,

or use a slow or medium blow fuse type. Total DC input power consumption of the 9850 is below 12 watts, and

is typically 7-8 watts.

AUX POWER AND SWITCHES

Aux Power is supplied through a pre-assembled cable (MSI P/N 13195). It provides for DC power in (7-25Vdc),

up to four switches, and a remote LED indicator. The LED indicator provides a remote indication that the 9850

is on and functioning. The switches and LED are supplied by the end user. In combination with the Set Points

Cable, the switch inputs can also be used with standard Isolated Input Modules.

Blue

Connect to Battery Negative or supply ground. It is generally best to connect this directly to the battery

or Power Supply negative terminal, or where the negative terminal is attached to the chassis.

Brown Connect to Battery or Power Supply Positive (7-25VDC). Again, a direct battery connection is usually

best to avoid interference with vehicle electrical systems. The CellScale is internally fused. If connected

to a breaker or fuse panel, use 2A at 12V, 1A at 24V. Fast blow or medium blow fuses are acceptable.

White Switch 1 input. Connect to a Normally Open push-button switch. The other switch terminal must con-

nect to the Blue wire (ground). If this feature is not used, insulate the end of the wire to prevent it from

shorting.

Black Switch 2 input. Connect to a Normally Open push-button switch. The other switch terminal must con-

nect to the Blue wire (ground). If this feature is not used, insulate the end of the wire to prevent it from

shorting.

Pink

Switch 3 input. Connect to a Normally Open push-button switch. The other switch terminal must con-

nect to the Blue wire (ground). If this feature is not used, insulate the end of the wire to prevent it from

shorting.

Gray Switch 4 input and/or Remote power indication. Connect to the anode of a remote LED. The LED cathode

must connect to the Blue wire (ground). No current limit resistor is required, current drive is provided by

the CellScale (~15mA). Suitable for LEDs with VF 1.6V to 2.4V@ 20mA. Not suitable for Blue or White

LEDs due to their VF >3V. If a fourth switch input is needed, connect to a Normally Open push-button

switch. If this wire is not used, insulate the end of the wire to prevent it from shorting. It is possible to

have the external LED in parallel with SW4. To do this, place a silicon diode (1N4148 or equivalent) in

series with the LED and place the Diode LED assembly across the switch. The current to the LED will

reduce to ~ 9mA (using a AlGaAs Red LED).