Zero, Zeroing zeroed – Rice Lake MSI-9850 CellScale RF Digital Indicator - Operator Manual User Manual

Page 31

Advertising
background image

MSI CellScale

®

System • 9850 User Guide Page 31

MEASUREMENT SYSTEMS INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

To Switch Between Multi-Channel Display and Single Channel Displays

1) Highlight the channel you wish to see in the single channel mode by pressing the UP (

^

) or DOWN (

v

)

cursor keys.

2) Once highlighted press

DISPLAY

. The highlighted channel will appear in the single channel mode.

3) Perform any scale function while in the single channel mode.
4) To return to the multi-channel display, press

DISPLAY

.

Multi-Channel Page Display
When a multi-channel display mode is selected that shows fewer channels than are available from the CellScale,

the user can view all channels with the page mode.
Any channel can appear on any page by changing the preset channel using the “To Change Scale Channel...”

procedure. This allows a primary channel to show always, and secondary channels to change using the

ALPHA

key. This applies very well to the 3 channel preset display where one channel is large and the other 2 channels

are small.
To Change to the Next Page

Press the

ALPHA

key. The next group of channels appears. The action of the

ALPHA

key is circular, return-

ing to page 1 after the last page.

To Copy the Current Page

Sometimes it is advantageous to copy the current page and then make channel changes on the new page.

1) Press the

ENTER

key. The entire screen will reverse.

2) Press the

ALPHA

key. The new copied page will appear. Make modifications with the enter channel pro-

cedures as desired.

To Delete the Current Page

1) Press the

[0]

(SPACE)

key.

2) Press the

ALPHA

key. The current page will be deleted and the display will revert to the first page.

The 9850 will not allow the deletion of the last remaining page.

To Move Around in Pages

If you have many preset pages, you can move directly to pages by number entry.

1) Enter the number corresponding to the page you wish to see.
2) Press the

ALPHA

key. The new page will appear.

1) In single channel mode, go to step 2. In multi-channel mode, highlight a channel

with the up (

^

) or down (

v

) cursor keys to make it active.

2) Press

ZERO

. The weight reading must be stable within the motion window for

the zero function to work. The display temporarily reads “ZEROING” and then

“ZEROED” after the CellScale acknowledges the command. The scale digits

display 0 (or 0.0 or 0.00, etc..). The backup memory in the CellScale stores the

zero reading, and can restore it even if power fails.

The “ZEROING” and “ZEROED” messages may not be displayed on every zero request if the CellScale responds
instantly, but the scale will zero.

ZERO

0

ZEROING

ZEROED

ZERO

Sets the zero reading of the scale. Use the

ZERO

key to take out small deviations in zero when the scale is

unloaded. (See “TARE SET” for zeroing (Taring) package or pallet weights)
To Zero

Zero Rules for Use:

1) Works in GROSS mode or NET mode. Zeroing while in Net mode will zero the gross weight causing the display

to show the negative Tare value.

2) The scale must be stable within the Motion window. The scale will not zero if the motion detect annunciator

is on. The CellScale will “remember” that it has a zero request for 2 seconds. If motion clears in that time,

Go to Index