Custom display setup – Rice Lake MSI-9850 CellScale RF Digital Indicator - Operator Manual User Manual

Page 61

Advertising
background image

MSI CellScale

®

System • 9850 User Guide Page 61

MEASUREMENT SYSTEMS INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

CUSTOM DISPLAY SETUP

The 9850 weight display is fully customizable. Both the single channel and multi-channel displays can be custom-

ized. All available data types plus custom text can be located anywhere on the screen in any of three font sizes: 1)

Large Font – Used primarily for weight displays, the large font offers up to 8 characters in two rows. When used

as a weight display the 9850 automatically fits in mode (Net, Gross, Tare), motion, COZ, and units in smaller

characters. 2) Medium Font – Used for all data types, the medium font offers up to 16 characters in 4 rows. 3)

Small Font – Used for all data types, the small font offers up to 20 characters in 8 rows.

Planning Your Custom Display
Decide what type of data you wish to see and what is the most important data. This important data could be dis-

played in the large or medium fonts, and other less important data should be displayed in the small font. Use the

text mode to label function keys with custom titles to aid in the operation of your system.

For example, use text to label line 7 “F3 Customer” and place ID String 1 next to it. Then use text to label line 8 “F4 Operator” and place ID String 2 next to it.
Program the F keys to match. Now you have an easy way to enter your required data.

If your system has multiple channels, make sure you provide both a single channel and multiple channel display

setup. In multi-channel displays, it is usually best to supply the same data for each individual channel display

similar to avoid confusion. However, if one channel is primary, it is easy to distinguish it by making it larger than

other channels. In any multi-channel screen, you can display from 2 to 8 channels, assuming that the CellScale

Scan List includes at least 8 channels. CellScales with more than eight channels use the page mode to observe

all channels. Select a preset display that is closest to your needs, then edit it. If no preset display is close, use the

“CLR Screen” command to start from a completely empty display.

A space is reserved for the enter number field, which can be overwritten with other types of data.

Data Types & Sizes

Type

Lg Font Med Font Sm Font

Description

Min Max Min Max Min Max

Weight

- 8 - 14 - 14 Current Weight in Net or Gross with Units, Motion, and COZ

indicators.

Gross-Wt

- 8 - 11 - 11 Gross Weight only

Tare-Wt

- 8 - 11 - 11 Tare Weight only

CHN

- 3 - 3 - 3 Channel number in the form X-X. e.g. 1-1. The Channel number

is determined by the CellScale Scan List.

ADR

2 3 2 3 2 3 Network Address in the form of XXA. e.g. 17A

Ch-Name

2 8 2 16 2 20 Channel Name. The Channel Name is programmed in the

CellScale.

DateTime

N/A

- 16 - 16 Shows the Date and Time. When in the form “DateTimeEnter-

Number” it may be overwritten when entering a number with the

keypad.

Date

5 8 5 10 5 10 Date in 5 characters does not include year. In 8 characters includes

2 digit year. In 10 characters includes 4 digit year.

Time

5 8 5 10 5 10 Time in 5 characters does not include seconds. Time in 7 Characters

adds AM/PM. Time in 8 characters includes seconds (no AM/PM).

Time in 10 characters includes seconds and AM/PM.

1-ID-String

- 8 8 16 8 20 Show ID string 1.

2-ID-String

- 8 8 16 8 20 Show ID string 2.

Total-Wt-ID

- 8 - 15 - 15 Shows the Total weight stored in the current ID Code.

#-SamplesI

- 8 - 10 - 10 Shows the number of samples totaled and used for statistics for the

current ID Code.

IDC

2 3 2 3 2 3

The ID Code number in the form xxI. e.g. 2I is

ID Code 2.

IDName--

2 8 2 8 2 8 The ID Code name. The name must be programmed by either the

CellScale or the 9850.

xS or xSL

2 3 2 3 2 3 Scan List Index position displayed in the form xSL (positions 1-9)

or xxS (positions 10-32).

Grand-Ttl-Wt

- 8 - 15 - 15 Grand Total Weight from all IDs on the active channel.

Gd-Samples

- 8 - 10 - 10 Grand Number of Samples from all IDs on the active channel.

BarCode-String - 8 8 16 8 20 Bar Code Entry Display

Text

1 8 1 16 1 20 Generic fixed text. Does not change with channels or IDs.

Go to Index