Page 32 MSI-9850 RF Remote Indicator • User Guide

MSI-9850

HANDHELD RF REMOTE INDICATOR for

C

ELL

S

CALE

®

the scale will zero.

3) The scale will accept a zero setting over the full Range of the scale (NTEP and other Legal-for-trade models may

have a limited zero range). Zero settings above 4% of full scale will subtract from the overall capacity of the scale.

For example if you zero out 100 lb. on a 1000 lb. scale the overall capacity of the scale will reduce to 900 lb. plus

the allowed over-range amount.

TARE

Tare is typically used to zero out a known weight such as a packing container or pallet and display the load in

NET weight. A Tare value is entered in either of two ways:

1) PUSH BUTTON TARE – When the

TARE

key is pressed, the current weight is zeroed and Net Weight is

displayed.

2) KEYBOARD TARE – Using the numeric keys, the operator keys in the desired Tare Weight then presses the

TARE

Key.

For Pushbutton Tare

To Clear Tare and Revert to Gross Mode

If the goal is to see the Gross Weight, use the Net/Gross key instead.

TARE

T

TARING

1) In single channel mode, go to step 2. In multi-channel mode, highlight a channel

with the up (

^

) or down (

v

) cursor keys to make it active.

2) Press

TARE

. The current Gross Weight will be stored in the Tare register and

the weight mode will change to NET (single display modes).

0

SPACE

TARE

T

1) In single channel mode, go to step 2. In multi-channel mode, highlight a channel with the

up (

^

) or down (

v

) cursor keys to make it active.

2) Press

[0]

followed by

TARE

. The Tare value will clear and the scale returns to the GROSS

mode.

Alternate method: Remove all weight from the scale (Gross Zero) and press TARE. The message display temporarily reads “TARING”.
Then the scale returns to the GROSS mode.

To Keyboard Tare

To View the Tare Value on the LED Display

The default function for ENTER-NET/GROSS is “View Tare”. This function can also be assigned to any F-Key.

2

0

SPACE

EXIT

5

MNO

3

TARE

T

1) In single channel mode, go to step 2. In multi-channel mode, highlight a channel with

the up (

^

) or down (

v

) cursor keys to make it active.

2) Using the numeric keys input the value desired. In this example we’ll use 0.5 lb. as

a Tare Value. Press

[0] [.] [5]

. The Enter Line displays “0.5”.

You must place a leading zero if the Tare value is less than 1.

3) Press

TARE

to place the value in the Tare Register (Current Channel, current ID).

The display reads “TARE SET” when the CellScale responds. All subsequent read-

ings have the Tare value subtracted and are displayed in “NET” weight.

To View and/or Change the Tare Value

2

ENTER

TARE

T

1) In single channel mode, go to step 2. In multi-channel mode, highlight a channel with

the up (

^

) or down (

v

) cursor keys to make it active.

2) Press

ENTER

followed by

TARE

.

3) The display shows the current Tare value for 5 seconds

You can edit the Tare value from this screen by pressing number keys.

2

ENTER

TARE

T

1) In single channel mode, go to step 2. In multi-channel mode, highlight a channel with

the up (

^

) or down (

v

) cursor keys to make it active and place it on the LED.

2) Press

ENTER

followed by

DISPLAY

.

3) The LED display shows the current Tare value for 5 seconds

Go to Index