Setup total menu – Rice Lake MSI-9850 CellScale RF Digital Indicator - Operator Manual User Manual

Page 49

Advertising
background image

MSI CellScale

®

System • 9850 User Guide Page 49

MEASUREMENT SYSTEMS INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

Auto Total Operation

1) Enable the desired Auto Total mode in the “SETUP TOTAL” menu (see “SETUP TOTAL”). Select the

“AUTONORM”, “AUTOLOAD”, or the “AUTOPEAK” mode. Exit from the setup menu.

2) Use the

TOTAL

key to disable (“TTL OFF”) or enable (“TTL ON”) Auto Total.

3) Place the weight to be totaled on the scale.

4) Remove the weight. The screen will read “TOTALING” briefly, then return to the weight display.

The total key is used as a Total On, Total Off, toggle key which is indicated briefly on the message display (i.e. “TOTAL ON” or “TOTAL OFF”). Auto Totaling
will only occur in the TOTAL ON mode. This feature allows the user to turn off Auto Total for periods in which the scale needs to be used without adding to
the total. Turning the Auto Total off does not erase the current total. See “To Clear the Total Value” to learn how to erase the Total.

Rules for Auto Total:

1) Cannot be in motion. The weight must settle within the motion window.

2) Weight readings must be greater than the set High Total Threshold.

3) Each reading added to total must be preceded by a return to net or gross zero (below the Low Total Thresh-

old).

SETUP TOTAL MENU

Allows setting Totalizing parameters.

SETUP SELECT MENU

1 Function Keys

2 Set Points

3 System

4 Password Locks

5 Display Preview

6 Total

7 MORE 1/2

TOTAL MODE

1 Disabled

2 Auto Load

3 Auto Norm

4 Auto Peak

5 On Accept

6 Manual

7 Load Drop

TOTAL SETTINGS

--Chan Name--

1 Mode DISABLED

2 Motion Check ON

3 High Threshold 11%

4 Low Threshold 10%

HIGH TOTAL THRESHOLD

ESC exits no change

ENTER saves value

0-9 replaces value

min = 1, max = 100

^ incs, v decs value

LOW TOTAL THRESHOLD

ESC exits no change

ENTER saves value

0-9 replaces value

5

min = 0, max = 99

^ incs, v decs value

2 Motion Check ON

2 Motion Check OFF

SETUP SELECT MENU

TOTAL SETTINGS

TOTAL MODE

HIGH TOTAL THRESHOLD

LOW TOTAL THRESHOLD

or

ESC

!

SETUP

F1

TOTAL

6

PQR

2

DEF

1

ABC

3

GHI

4

JKL

[1]

TOTAL MODE – The Manual mode requires

that the

TOTAL

key is pressed when the weight

currently on the scale should be added to the

previously accumulated value. See description

on previous page of the 7 total modes.

[2]

TOTAL MOTION – Enables or disables Motion

Detection for Manual Total. Has no effect on

AUTOTOTAL. This menu item controls whether

the scale has to be out of motion before it will

total. In certain high vibration applications it is

sometimes desirable to turn off the motion detect

so that Totalizing can occur. This feature is dis-

abled for legal-for-trade systems.

[3]

HIGH TOTAL THRESHOLD –

[4]

LOW TOTAL THRESHOLD –

Sets the weight value above which Totalizing is

allowed. For example, setting the high threshold

to 10% on a 200 kg scale will set the threshold at

20 kg. Only weight above 20 kg will add to the

Total. Once totaled, the weight must return below

the Low Threshold to enable the next totalizing.

This prevents the same weight from being totaled

twice. Another example: On a scale with a capac-

ity of 1000 kg the user desires to Auto Total all

weight that exceeds 50 kg. Since 50 kg is 5% of

1000 kg, the Total Threshold is set to 5%. The

Threshold is entered in 1% increments.

Minimum Thresholds are 1% for the high, and 0% for the low.