Set points, Msi-9850 – Rice Lake MSI-9850 CellScale RF Digital Indicator - Operator Manual User Manual

Page 110

Advertising
background image

Page 110 MSI-9850 RF Remote Indicator • User Guide

MSI-9850

HANDHELD RF REMOTE INDICATOR for

C

ELL

S

CALE

®

SET POINTS

1 S 9 S 17 S 25 S

2 S 10 S 18 S 26 S

3 S 11 S 19 S 27 S

4 S 12 S 20 S 28 S

5 S 13 S 21 S 29 S

6 S 14 S 22 S 30 S

7 S 15 S 23 S 31 S

8 S 16 S 24 S 32 S

SP1-NameS SP9 Name-S

SP2-NameS SP10Name-S

SP3-NameS SP11Name-S

SP4-NameS SP12Name-S

SP5-NameS SP13Name-S

SP6-NameS SP14Name-S

SP7-NameS SP15Name-S

SP8-NameS SP16Name-S

2 Set Points DISABLED

2 Set Points ENABLED

5 Clear Latches

Cleared

OPERATOR 1 SP XX

1 Greater Than >

2 > or Equal >=

3 Less Than <

4 < or Equal <=

5 Off

SET POINT VALUE 1

ESC exits no change

ENTER saves value

0-9 replaces value

500

min = 0, max =CAP

^ incs, v decs value

VALUE 1 TYPE

SP

XX

1 Gross

2 Net or Gross

3 Total

4 # of Totals

PREACT VALUE

ESC exits no change

ENTER saves value

0-9 replaces value

10

min = 0, max = CAP

^ incs, v decs value

4 Relationship OR

4 Relationship AND

4 Relationship NONE

VIEW FORMULA SP XX

Set Pt Triggers If

N/G Wt >= 500.0

AND N/G Wt <=1000.0

Set Pt Resets If

N/G Wt < 500.0

OR N/G Wt > 1000.0

1 SP

XX

-SPName- OFF

2 9750 Response

OFF

3 Input Source

XX

4 Output Assign

XX

5 Delay

XXXXXms

6 Latch

OFF

7 Force On

OFF

8 Formula 9 View

AUDIBLE ALARMS SPXX

TRIP RESET

1 Off 6 Off

2 High F 7 High F

3 Med F 8 Med F

4 Low F 9 Low F

5 Warble 0 Warble

F3 Test F4 Test

Len 0 F4 Menu

Max 20 ENT Save

Pos 1

-Alarm String-

ALARM DISPLAY SP XX

TRIP RESET

1 Off 6 Off

2 Large 7 Large

3 Medium 8 Medium

4 Small 4 Small

5 Edit 0 Edit

F3 Test F4 Test

1

ALARM TO COMM1 SP XX

TRIP RESET

1 Off 4 Off

2 On 5 On

3 Edit 6 Edit

F3 Test F4 Test

INPUT SCAN LIST LOC

ESC exits no change

ENTER edits value

0-9 replaces value

1

min = 1 max = 32

^ incs, v decs value

SET POINT DELAY ms

ESC exits no change

ENTER saves value

0-9 replaces value

1000

min = 0, max =10000

^ incs, v decs value

SET POINT XX

1 Audible Alarms OFF

2 Alarm Display OFF

3 Alarm to Comm 2 OFF

SET POINT OUTPUT LIST

ESC exits no change

ENTER edits value

0-9 replaces value

1

min = 1 max = 32

^ incs, v decs value

1 SP

XX

-SPName- ON

1 SP

XX

-SPName- OFF

Len 0 F4 Menu

Max 8 ENT Save

Pos 1

SETPOINT

XX

NAME

1

6 Latch ON

6 Latch OFF

7 Force Output ON

7 Force Output OFF

FORMULA SP XX

1 Operator 1

>

2 Value 1

XXXXXXX

3 Val 1 Type

GROSS

4 Dual Value

OFF

5 Preact

XXXXXXX

6 Deadzone

XXXXXXX

7 View Formula

INPUT SCAN LIST LOC

ESC exits no change

ENTER edits value

0-9 replaces value

1

min = .1 max = 32

^ incs, v decs value

Edit

See General Text Editing

Procedure

1, 2, & 3 menus are similar to Value 1 menus

To Edit Highlighted

Set Point Name

0-9

or

Cursors

0-9

or

Cursors

MASTER SET POINTS

1 Program Set Point

2 Set Points

ENABLED

3 View Status

4 View Status w/Name

5 Clear Latches

6 Mom Timeout Ш.Ш s

PROGRAM SET POINT

ESC exits no change

ENTER edits value

Ø-9 replaces value

1

min = 1 max = 32

^ incs, v decs value

See General Text Editing

Procedure

VALUE 2 ENTRY SP XX

1 Operator 2

>

2 Value 2

XXXXXXX

3 Val 2 Type

GROSS

4 Relationship

to Value 1

AND

5 View Formula

Input Set Point

# for programming

(1-32)

MASTER SET POINTS

ESC

!

SETUP

2

DEF

2

DEF

1

ABC

3

GHI

4

JKL

8

VWX

5

MNO

1

ABC

1

ABC

2

DEF

ALPHA

A

a

1

ALPHA

A

a

1

ALPHA

A

a

1

2

DEF

3

GHI

3

GHI

5

MNO

4

JKL

6

PQR

7

STU

5

MNO

4

JKL

6

PQR

7

STU

1

ABC

2

DEF

3

GHI

4

JKL

ENTER

PROGRAM SET POINT

FORMULA SP

XX

OPERATOR 1 SP

XX

SET POINT VALUE 1

VALUE 1 TYPE SP

XX

VALUE 2 ENTRY SP

XX

PREACT

VIEW FORMULA SP

XX

SET POINT DELAY ms

ALARM TO COMM2 SP

XX

ALARM DISPLAY SP

XX

AUDIBLE ALARMS SP

XX

SET POINT

XX

SET POINT OUTPUT LIST

INPUT SCAN LIST LOC

MOMENTARY TIMEOUT

6

PQR

Go to Index

Advertising
This manual is related to the following products: